{"id":2507,"date":"2021-12-29T09:33:39","date_gmt":"2021-12-29T09:33:39","guid":{"rendered":"https:\/\/cstcoegypt.com\/?p=2507"},"modified":"2022-11-08T10:33:24","modified_gmt":"2022-11-08T10:33:24","slug":"aw-cfp2166-4","status":"publish","type":"post","link":"https:\/\/cstegypt.com\/?p=2507","title":{"rendered":"AW-CFP2166-4"},"content":{"rendered":"<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-2508\" src=\"https:\/\/cstegypt.com\/wp-content\/uploads\/2021\/12\/AW-CFP2166-4.jpg\" alt=\"\" width=\"220\" height=\"250\" \/><\/p>\n<p><img loading=\"lazy\" class=\"wp-image-6680 alignnone\" src=\"https:\/\/cstegypt.com\/wp-content\/uploads\/2021\/12\/download.png\" alt=\"\" width=\"68\" height=\"43\" \/>\u00a0 \u00a0 \u00a0 <img loading=\"lazy\" class=\"alignnone wp-image-6682\" src=\"https:\/\/cstegypt.com\/wp-content\/uploads\/2021\/12\/275485189_687810405909359_5434635192700911188_n.jpg\" alt=\"\" width=\"104\" height=\"40\" \/><\/p>\n<hr \/>\n<div class=\"art_bor\">\n<div class=\"main\">\n<div class=\"art_title\"><span style=\"font-size: 19px;\"><strong>Product Features<\/strong><\/span><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<div class=\"main\">\n<div class=\"p_del\">\n<div><strong>4 Zone Fire Alarm Control Panel Specification<\/strong><\/div>\n<div><strong>1. It is modularized design, the panel can expend from 1 zone to 32 zones easily.<\/strong><\/div>\n<div><strong>2. It has 2 level control mode by a lock<\/strong><\/div>\n<div><strong>3. It has 24VDC and 5VDC power supply output.<\/strong><\/div>\n<div><strong>4. It has FIRE and FAULT signal output.<\/strong><\/div>\n<div><strong>5. It has 2 general sounders output.<\/strong><\/div>\n<div><strong>6. Each zone has 1 circuit detectors input<\/strong><\/div>\n<div><strong>7. Each zone can be disable by a button.<\/strong><\/div>\n<div><strong>8. It has RESET button to reset the panel.<\/strong><\/div>\n<div><strong>9. It has SILENCE button to stop BUZZER and SOUNDERS.<\/strong><\/div>\n<div><strong>10. It has EVACUATE button to start a manual fire alarm immediately.<\/strong><\/div>\n<div><strong>11. It has battery low protection function, when battery voltage lower than 21VDC<\/strong><\/div>\n<div><strong>battery will be cut off automatically until the mains power is on.<\/strong><\/div>\n<div><strong>12. It has an optional GSM module for fire alarm by SMS<\/strong><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<div>\n<hr \/>\n<\/div>\n<div>\n<div class=\"art_bor\">\n<div class=\"main\">\n<div class=\"art_title\"><span style=\"font-size: 19px;\"><strong>Technical parameters<\/strong><\/span><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<div class=\"main\">\n<div class=\"p_del\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>AC INPUT<\/td>\n<td>220VAC 50HZ<\/td>\n<td>+10%<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>-15%<\/td>\n<\/tr>\n<tr>\n<td>DC OUTPUT<\/td>\n<td colspan=\"2\">24VDC typical<\/td>\n<\/tr>\n<tr>\n<td>Voltage for MCU<\/td>\n<td colspan=\"2\">5V for power board MCU, 3.3V for others<\/td>\n<\/tr>\n<tr>\n<td>Current at 24VDC from PSE<\/td>\n<td colspan=\"2\">450mA standby current<\/td>\n<\/tr>\n<tr>\n<td>Maximum current from PSE<\/td>\n<td colspan=\"2\">2A except batteries charge<\/td>\n<\/tr>\n<tr>\n<td>Batteries current<\/td>\n<td colspan=\"2\">1.85A maximum, current limited<\/td>\n<\/tr>\n<tr>\n<td>Auxiliary output<\/td>\n<td colspan=\"2\">24VDC +\/- 10%, 100 mA max,<br \/>\ncurrent limited, monitored<\/td>\n<\/tr>\n<tr>\n<td>Batteries<\/td>\n<td colspan=\"2\">2*12V\/ 2.3Ah sealed lead acid gel,<br \/>\nself-regulated<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">2*12V\/ 7Ah if needed<\/td>\n<\/tr>\n<tr>\n<td>Battery replace Resistance<\/td>\n<td colspan=\"2\">2\u03a9\u00b110% if needed<\/td>\n<\/tr>\n<tr>\n<td>Battery low-voltage protection<\/td>\n<td colspan=\"2\">22.2V<\/td>\n<\/tr>\n<tr>\n<td>Detectors connection allowed each zone<\/td>\n<td colspan=\"2\">20 (except MCPs)<\/td>\n<\/tr>\n<tr>\n<td>Zone alarm current<\/td>\n<td colspan=\"2\">6mA minimum\/ 27mA maximum<\/td>\n<\/tr>\n<tr>\n<td>Sounder output<\/td>\n<td colspan=\"2\">2*0.75A maximum<\/td>\n<\/tr>\n<tr>\n<td>Fire protection<\/td>\n<td colspan=\"2\">100mA maximum<\/td>\n<\/tr>\n<tr>\n<td>Fire routing<\/td>\n<td colspan=\"2\">100mA maximum<\/td>\n<\/tr>\n<tr>\n<td>Fault routing<\/td>\n<td colspan=\"2\">100mA maximum<\/td>\n<\/tr>\n<tr>\n<td>Communication protocol<\/td>\n<td colspan=\"2\">2 wires RS485 bus system<\/td>\n<\/tr>\n<tr>\n<td>Relay contacts rating<\/td>\n<td colspan=\"2\">Dry contacts (NO\/NC) 1A @24VDC<\/td>\n<\/tr>\n<tr>\n<td>EOL resistor for zone<\/td>\n<td colspan=\"2\">6.8K 1W<\/td>\n<\/tr>\n<tr>\n<td>EOL resistor for outputs<\/td>\n<td colspan=\"2\">6.8K 1W<\/td>\n<\/tr>\n<tr>\n<td>Fuse on power board<\/td>\n<td colspan=\"2\">3A\/ 250V glass tube fuse 20mm<\/td>\n<\/tr>\n<tr>\n<td>Fuse on EMI board<\/td>\n<td colspan=\"2\">1A\/ 250V glass tube fuse 20mm<\/td>\n<\/tr>\n<tr>\n<td>Environmental<\/td>\n<td colspan=\"2\">Class A temperature range: -5 to 40\u00b0C (23~104\u00b0F)<br \/>\nHumidity: 5 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Terminal blocks rating<\/td>\n<td colspan=\"2\">All terminals rated for 12 to18 AWG<br \/>\n(0.75 to 2.5 mm2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u00a0 \u00a0 \u00a0 Product Features 4 Zone Fire Alarm Control Panel Specification 1. It is modularized design, the panel can expend from 1 zone to 32 zones easily. 2. It has 2 level control mode by a lock 3. It has 24VDC and 5VDC power supply output. 4. It has FIRE and FAULT signal output. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/posts\/2507"}],"collection":[{"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cstegypt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2507"}],"version-history":[{"count":3,"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/posts\/2507\/revisions"}],"predecessor-version":[{"id":6704,"href":"https:\/\/cstegypt.com\/index.php?rest_route=\/wp\/v2\/posts\/2507\/revisions\/6704"}],"wp:attachment":[{"href":"https:\/\/cstegypt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2507"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cstegypt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2507"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cstegypt.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}